Pos 1: Combustion Fan with Burner Control Unit (BCU)
Current Consumption:
15 kW, direct start
Voltage:
440 V, 3 phases, ground, 63 A
Dimensions:
800 x 1200 mm (LxW), installed on wheels
Sound:
83 dBA
BCU: UV flame supervision, PLC controlled, alarm
Weight:
280 kg
Pos 2: Gas/Fuel Supply Station
Safety Components:
Double gas safety shutoff, pilot, pressure switch
Burner Cooling/Purging:
Compressed air max 1.5 bar, 5-10 Nm³/h
Max Flow:
300 Nm³/h
Max Pressure:
Inlet 4 bar max, internal pressure reducer to 0.5 bar
Weight:
25 kg
Couplings:
2" Camlock / ¼" Cooling Air
Pos 3: High-Speed Burner, Type HV3000 for Gas
Safety Components:
UV flame sensor, automatic ignition, pressure switch
Power:
300 Nm³/h of natural gas (approximately 3 MW)
Nozzle:
High-temperature steel (1250°C), optional nickel-free
Nozzle Dimensions:
200 x 200 mm (other dimensions on request)
Air Inlet:
250 mm
Gas Inlet:
2" Camlock
Weight:
25 kg
HV-3000

The HV3000 Heat Up Burners have a maximum capacity of 300 Nm³/h of natural gas and 5,800 Nm³/h of combustion air. They feature flame supervision by UV cells. In case of flame failure, the gas supply will be stopped within 2 seconds by safety shutoff solenoid valves.
- Doubled capacity for larger industrial heat-up applications.
- Versatile usage across multiple furnace types and refractory linings.
- Maintains uniform heat zones, reducing risk of cracking or stress.
- Portable design suitable for field use and plant integration.
- Compatible with multiple fuel types (gas or oil).
- Equipped with automated controls for precision heating.
- High durability even under continuous operation.
- Proven performance in cement, steel, glass, and non-ferrous industries.